Power Factor Correction ICs
- 
					
Status:Available
 
The FA5590N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has an FB short-circuit detection circuit that stops operation when an abnormality is detected by the output voltage detection unit.
Features
- Capable of low standby power by disabling input voltage detection
 - High-precision current detection: 0.6 V ± 5%
 - Improves efficiency under light loads using a maximum frequency limiting function
 - Prevents noise using a soft start and dynamic OVP circuit
 - Achieves low power consumption by using a high-voltage CMOS
- Startup of 80 μA (max), 2 mA (typ) during operation
 
 - Capable of directly driving power MOSFET, output peak current: source 1 A/sink 1 A
 - Stops switching even when an abnormality occurs in the output voltage detection line using an FB short-circuit detection circuit
 - Built-in low voltage malfunction prevention circuit (9.6 V ON/9 V OFF)
 - Restart timer
 - Standby function
 - Package: SOP-8
 
Applications
- Switching Power Supplies
 
Specifications
| Controller type | CRM PFC | 
|---|---|
| Applied circuit Detail | PFC (Boost)) | 
| Frequency | Selfoscillation | 
| VCC(V) | 10 to 26 | 
| OVP pin Detail | - | 
| Overload operation | No (with overcurrent protection) | 
| Overvoltage operation | Auto-Recovery (FB) | 
| Package | SOP-8 | 
Documentation Tools
| Datasheet | FA5590N | 
|---|---|
| Selection Guide | Power Supply Control IC Selection Guide | 