Type Search
Search Results
- Number of discontinued/maintenance products in parentheses ( )
Power Factor Correction IC
- Parametric search is not available for discontinued/maintenance products.
|
Device type
|
Datasheet |
Status
|
IC type | Overview | Comment |
|---|
| FA1B00N | Available | Power Factor Correction ICs | The FA1B00N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has an FB short-circuit detection circuit that stops operation when an abnormality is detected by the output voltage detection unit. | ||
| FA1B10N | Available | Power Factor Correction ICs | |||
| FA1B20N | Available | Power Factor Correction ICs | |||
| FA1C20N | Available | Critical conduction mode interleaved PFC control IC | FA1C20N is a power-factor correction converter IC operating in interleaved critical conduction mode. It achieves low power consumption by using a high-voltage CMOS process. It is equipped with many protection functions, such as an FB short-circuit detection circuit that stops operation when the feedback signal fails. In addition, it includes a coordination function with Fuji‘s current resonant control IC, the FA6CxxN series. It helps improve PSU efficiency when both ICs are used together. | ||
| FA1A00N | Available | Power Factor Correction ICs | The FA1A00N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has a redundant overvoltage protection function and output short-circuit protection circuit. | ||
| FA1A01N | Available | Power Factor Correction ICs | The FA1A01N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has a redundant overvoltage protection function and output short-circuit protection circuit. | ||
| FA1A10N | Available | Power Factor Correction ICs | The FA1A10N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has a frequency reduction function and output short circuit protection circuit. | ||
| FA1A11N | Available | Power Factor Correction ICs | The FA1A11N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has a frequency reduction function and output short circuit protection circuit. | ||
| FA1A21N | Available | Power Factor Correction ICs | The FA1A50N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has a redundant overvoltage protection function and FB short-circuit protection circuit. | ||
| FA1A50N | Available | Power Factor Correction ICs | The FA1A50N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has a redundant overvoltage protection function and FB short-circuit protection circuit. | ||
| FA1A60N | Available | Power Factor Correction ICs | The FA1A60N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has a frequency reduction function, redundant overvoltage protection function, and FB short circuit protection function. In addition, it has a built-in state setting function using an external signal, and when combined with our current resonance IC FA6B20N, it improves power supply efficiency and optimizes operation in accordance with input voltage. | ||
| FA1A61N | Available | Power Factor Correction ICs | The FA1A61N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has a frequency reduction function and redundant overvoltage protection function. In addition, it has a built-in state setting function using an external signal, and when combined with our current resonance IC FA6B21N, it improves power supply efficiency and optimizes operation in accordance with input voltage. | ||
| FA5502M | Available | Power Factor Correction ICs | The FA5502M is a control IC for power factor correction converters. It achieves low power consumption by using a high-voltage CMOS process. Since it uses an average value current control method, it is capable of stable operation and can easily achieve a power factor of 99% or higher. In addition, it can control the DC output voltage over a wide range of loads from the rated load down to no-load. | ||
| FA5590N | Available | Power Factor Correction ICs | The FA5590N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has an FB short-circuit detection circuit that stops operation when an abnormality is detected by the output voltage detection unit. | ||
| FA5591N | Available | Power Factor Correction ICs | The FA5591N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has an FB short-circuit detection circuit that stops operation when an abnormality is detected by the output voltage detection unit. | ||
| FA5612N | Available | Power Factor Correction ICs | FA5612 is a control IC for power factor correction converters. It achieves low power consumption by using a high-voltage CMOS process. Since it uses an average value current control method, it is capable of stable operation and can easily achieve a power factor of 99% or higher. In addition, it can control the DC output voltage over a wide range of loads from the rated load down to no-load. Furthermore, the line filter can be simplified by incorporating a proprietary switching frequency spread function. | ||
| FA5613N | Available | Power Factor Correction ICs | FA5613 is a control IC for power factor correction converters. It achieves low power consumption by using a high-voltage CMOS process. Since it uses an average value current control method, it is capable of stable operation and can easily achieve a power factor of 99% or higher. In addition, it can control the DC output voltage over a wide range of loads from the rated load down to no-load. Furthermore, the line filter can be simplified by incorporating a proprietary switching frequency spread function. | ||
| FA5696N | Available | Power Factor Correction ICs | The FA5696N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has a redundant overvoltage protection function and output short-circuit protection circuit. | ||
| FA5601N | Discontinued | Power Factor Correction ICs | The FA5601N is a control IC for configuring a critical-mode power factor correction converter. It achieves low power consumption by using a high-voltage CMOS process. It also has an FB short-circuit detection circuit that stops operation when an abnormality is detected by the output voltage detection unit. | ||
| FA5614N | Discontinued | Power Factor Correction ICs | FA5614 is a control IC for power factor correction converters. It achieves low power consumption by using a high-voltage CMOS process. Since it uses an average value current control method, it is capable of stable operation and can easily achieve a power factor of 99% or higher. In addition, it can control the DC output voltage over a wide range of loads from the rated load down to no-load. Furthermore, the line filter can be simplified by incorporating a proprietary switching frequency spread function. | ||
| FA5615N | Discontinued | Power Factor Correction ICs | FA5615 is a control IC for power factor correction converters. It achieves low power consumption by using a high-voltage CMOS process. Since it uses an average value current control method, it is capable of stable operation and can easily achieve a power factor of 99% or higher. In addition, it can control the DC output voltage over a wide range of loads from the rated load down to no-load. Furthermore, the line filter can be simplified by incorporating a proprietary switching frequency spread function. |



