Parametric Search

AC/DC Power Supply Control IC

  • Parametric search not available for discontinued/maintenance products.

Applicable Products: 64 Results(Total Number of Products: 64)
Displaying 1-20

Results display

Device type
Datasheet
New product
IC type
Controller type
Control mode
Applied circuit Detail
Frequency (kHz)
VCC(V)
Built-in start up circuit (V)
Brown out function Detail
Over load protection
Over voltage protection
Green mode function
Package
Current sense
Function
VCC on-voltage(V)
VCC off-voltage(V)
-
-
FA5680N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 11 to 24 750 Without Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Negative 18 8
FA5681N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 11 to 24 750 Without Timer-latch Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Negative 18 8
FA8A00N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 12 to 24 500 With (Fixed) Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 13 6.5
FA8A01N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 12 to 24 500 With (Fixed) Timer-latch Delay 70 ms Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 13 6.5
FA8A12N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 12 to 24 500 Without Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 13 6.5
FA8A27N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 28 500 With (Fixed) Timer-latch Delay 860 ms Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 13 6.5
FA8A37N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 28 500 With (Fixed) Timer-latch Delay 1.6 s Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 13 6.5
FA8A39N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 28 500 With (Fixed) Timer-latch Delay 2.5 s Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 13 6.5
FA8A40N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 100 12 to 24 500 With (Fixed) Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 13 6.5
FA8A41N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 100 12 to 24 500 With (Fixed) Timer-latch Delay 70 ms Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 13 6.5
FA8A60N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 24 500 Without Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive 12.5 6.5
FA8A61N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 24 500 Without Timer-latch Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive 12.5 6.5
FA8A64N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 100 10 to 24 500 Without Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive 12.5 6.5
FA8A65N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 100 10 to 24 500 Without Timer-latch Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive 12.5 6.5
FA8A70N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 24 500 Without Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 12.5 6.5
FA8A71N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 24 500 Without Timer-latch Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 12.5 6.5
FA8A74N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 100 10 to 24 500 Without Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 12.5 6.5
FA8A75N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 100 10 to 24 500 Without Timer-latch Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 12.5 6.5
FA8A80N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 24 650 Without Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive 12.5 6.5
FA8A81N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 24 650 Without Timer-latch Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive 12.5 6.5
FA8A83N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 24 650 With (Fixed) Timer-latch Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 12.5 6.5
FA8A84N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 100 10 to 24 650 Without Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive 12.5 6.5
FA8A85N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 100 10 to 24 650 Without Timer-latch Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive 12.5 6.5
FA8A86N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 100 10 to 24 650 With (Fixed) Auto-Recovery - Linearly frequency reduction, Intermittent operation SOP-8 Positive 12.5 6.5
FA8A87N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 24 650 Without Timer-latch Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 12.5 6.5
FA8A90N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 24 650 Without Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 12.5 6.5
FA8A91N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 10 to 24 650 Without Timer-latch Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 12.5 6.5
FA8A94N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 100 10 to 24 650 Without Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 12.5 6.5
FA8A95N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 100 10 to 24 650 Without Timer-latch Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 12.5 6.5
FA8B16N
- Green mode PWM-ICs (Current mode) PWM Current mode Flyback 65 12 to 24 500 With (Fixed) Auto-Recovery Latch Vcc detection Linearly frequency reduction, Intermittent operation SOP-8 Positive X-Cap discharge function 12.5 8
FA8C71N NEW
New product Green mode PWM-ICs (Current mode)
FA13842N
- General PWM-ICs PWM Current mode Flyback External settings 10-500 kHz 10 to 25 Without Without Without (With over current protection) - - SOP-8 Positive 16.5 9
FA13843N
- General PWM-ICs PWM Current mode Flyback External settings 10-500 kHz 10 to 25 Without Without Without (With over current protection) - - SOP-8 Positive 9.6 9
FA13844N
- General PWM-ICs PWM Current mode Forward External settings 5-250 kHz 10 to 25 Without Without Without (With over current protection) - - SOP-8 Positive 16.5 9
FA13845N
- General PWM-ICs PWM Current mode Forward External settings 5-250 kHz 10 to 25 Without Without Without (With over current protection) - - SOP-8 Positive 9.6 9
FA3641N
- General PWM-ICs PWM Voltage mode Flyback External settings 30-500 kHz 10 to 28 Without Without Timer-latch CS latch, Vcc voltage detection Frequency reduction SOP-8 Positive Frequency reduction at light load 16.5 9
FA3647N
- General PWM-ICs PWM Voltage mode Flyback External settings 30-500 kHz 10 to 28 Without Without Timer-latch CS latch, Vcc voltage detection Frequency reduction SOP-8 Negative Frequency reduction at light load 16.5 9
FA5504N
- General PWM-ICs PWM Voltage mode Forward External settings 10-500 kHz 10 to 28 Without Without Timer-latch CS latch, Vcc voltage detection - SOP-8 Positive With error amplifier 16.5 9
FA5510N
- General PWM-ICs PWM Voltage mode Forward External settings 10-500 kHz 10 to 28 Without Without Timer-latch CS latch, Vcc voltage detection - SOP-8 Positive 16.5 9
FA5511N
- General PWM-ICs PWM Voltage mode Flyback External settings 10-500 kHz 10 to 28 Without Without Timer-latch CS latch, Vcc voltage detection - SOP-8 Positive 16.5 9
FA5515N
- General PWM-ICs PWM Voltage mode Flyback External settings 10-500 kHz 10 to 28 Without Without Timer-latch CS latch, Vcc voltage detection Intermittent operation SOP-8 Negative 16.5 9
FA5604N
- General PWM-ICs PWM Voltage mode Forward External settings 100-300 kHz 10 to 30 Without Without Auto-Recovery CS latch (External detection) - SOP-8 Negative Overcurrent limit correction function, Frequency reduction start/stop FB voltage under light load 1.80V/1.95V 17.5 9.7
FA5605N
- General PWM-ICs PWM Voltage mode Flyback External settings 100-300 kHz 10 to 30 Without Without Auto-Recovery CS latch (External detection) - SOP-8 Negative Overcurrent limit correction function, Frequency reduction start/stop FB voltage under light load 1.80V/1.95V 17.5 9.7
FA5606N
- General PWM-ICs PWM Voltage mode Flyback External settings 100-300 kHz 10 to 30 Without Without Auto-Recovery CS latch (External detection) - SOP-8 Negative Overcurrent limit correction function, Frequency reduction start/stop FB voltage under light load 1.55V/1.65V 17.5 9.7
FA5607N
- General PWM-ICs PWM Voltage mode Flyback External settings 100-300 kHz 10 to 30 Without Without Auto-Recovery CS latch (External detection) Intermittent operation SOP-8 Negative Overcurrent limit correction function 17.5 9.7
FA5570N
- Green mode Quasi-resonant ICs (Current mode) QR Current mode Flyback Selfoscillation (Max.120kHz) 10 to 28 500 Without Auto-Recovery - Intermittent operation SOP-8 Positive Without Over voltage protection 18 8
FA5571N
- Green mode Quasi-resonant ICs (Current mode) QR Current mode Flyback Selfoscillation (Max.120kHz) 10 to 28 500 Without Auto-Recovery Latch, ZCD voltage detection Intermittent operation SOP-8 Positive Over voltage protection, Latch 18 8
FA5573N
- Green mode Quasi-resonant ICs (Current mode) QR Current mode Flyback Selfoscillation (Max.120kHz) 10 to 28 500 Without Auto-Recovery Latch, ZCD voltage detection Linearly frequency reduction SOP-8 Positive 18 8
FA5577N
- Green mode Quasi-resonant ICs (Current mode) QR Current mode Flyback Selfoscillation (Max.120kHz) 10 to 28 500 Without Auto-Recovery Latch, Vcc voltage detection Linearly frequency reduction SOP-8 Positive Overvoltage Vcc detection 18 8
FA5640N
- Green mode Quasi-resonant ICs (Current mode) QR Current mode Flyback Selfoscillation (With control of bottom skips) 11 to 26 500 Without Auto-Recovery Latch, ZCD voltage detection Intermittent operation SOP-8 Positive 14 8
FA5641N
- Green mode Quasi-resonant ICs (Current mode) QR Current mode Flyback Selfoscillation (With control of bottom skips) 11 to 26 500 Without Auto-Recovery Latch, ZCD voltage detection Intermittent operation SOP-8 Positive Min. frequency limitation 14 8
FA5642N
- Green mode Quasi-resonant ICs (Current mode) QR Current mode Flyback Selfoscillation (With control of bottom skips) 11 to 26 500 Without Auto-Recovery Latch, ZCD voltage detection Intermittent operation SOP-8 Positive Vcc on-voltage (10V) 10 8
FA5643N
- Green mode Quasi-resonant ICs (Current mode) QR Current mode Flyback Selfoscillation (With control of bottom skips) 11 to 26 500 Without Auto-Recovery Latch, ZCD voltage detection Intermittent operation SOP-8 Positive Min. frequency limitation, Latch stop function (IS pin) 14 8
FA5644N
- Green mode Quasi-resonant ICs (Current mode) QR Current mode Flyback Selfoscillation (With control of bottom skips) 11 to 26 500 Without Timer-latch Latch, ZCD voltage detection Intermittent operation SOP-8 Positive 14 8
FA5648N
- Green mode Quasi-resonant ICs (Current mode) QR Current mode Flyback Selfoscillation (With control of bottom skips) 11 to 26 500 Without Auto-Recovery Latch, ZCD voltage detection Intermittent operation SOP-8 Positive For High SW frequency 14 8
FA6A00AN
- Current Resonant ICs LLC - Current resonance LLC (half bridge) Selfoscillation 14 to 27 600 With (Fixed) Auto-Recovery Timer-latch Intermittent operation SOP-16 Positive-Negative X-Cap discharge function 12 9
FA6A10N
- Current Resonant ICs LLC - Current resonance LLC (half bridge) Selfoscillation 14 to 27 600 With (Adjustable) Auto-Recovery Timer-latch Intermittent operation SOP-16 Positive-Negative X-Cap discharge function 12 9
FA6A11N
- Current Resonant ICs LLC - Current resonance LLC (half bridge) Selfoscillation 14 to 27 600 With (Adjustable) Timer-latch Timer-latch Intermittent operation SOP-16 Positive-Negative X-Cap discharge function 12 9
FA6A30N
- Current Resonant ICs LLC - Current resonance LLC (half bridge) Selfoscillation 14 to 27 600 With (Adjustable) Auto-Recovery Timer-latch Intermittent operation SOP-16 Positive-Negative X-Cap discharge function 13 9
FA6A31N
- Current Resonant ICs LLC - Current resonance LLC (half bridge) Selfoscillation 14 to 27 600 With (Adjustable) Timer-latch Timer-latch Intermittent operation SOP-16 Positive-Negative X-Cap discharge function 13 9
FA6B19N
- Current Resonant ICs LLC - Current resonance LLC (half bridge) Selfoscillation 14 to 29 600 With (Fixed) Auto-Recovery Auto-Recovery (VCC) Intermittent operation SOP-16 Positive-Negative 14 9
FA6B20N
- Current Resonant ICs LLC - Current resonance LLC (half bridge) Selfoscillation 14 to 29 600 With (Fixed) Auto-Recovery Auto-Recovery (VCC) Intermittent operation SOP-16 Positive-Negative X-Cap discharge function 14 9
FA6B21N
- Current Resonant ICs LLC - Current resonance LLC (half bridge) Selfoscillation 14 to 29 600 With (Fixed) Auto-Recovery Auto-Recovery (VCC) Intermittent operation SOP-16 Positive-Negative X-Cap discharge function 14 9
FA6B22N
- Current Resonant ICs LLC - Current resonance LLC (half bridge) Selfoscillation 14 to 29 600 With (Fixed) Auto-Recovery Auto-Recovery (VCC) Intermittent operation SOP-16 Positive-Negative X-Cap discharge function 14 9

Applicable Products: 64 Results(Total Number of Products: 64)
Displaying 1-20

Results display